Trinity High Flow Cartridges address one of the critical needs of the industry for absolute filtration at high flow rates. These cartridges consist of a radial pleat which maximizes the filtration area and also supports higher flow rates. Trinity High Flow Filter Cartridges are a direct replace mentto the Pall Ultipleat and 3M Cuno High-Flow Systems and are available in various end configurations to suit individual needs.
FEATURES AND BENEFITS
Filter Specification
Support & drainage Layer |
Polypropylene (PP) |
Inner Core |
Polypropylene (PP) |
End Caps |
Polypropylene (PP) |
Removal Ratings |
0.5, 1, 2, 5, 10, 25, 40, 70 micron |
O Rings / Gaskets(for SOE): |
Buna N, EPDM, Silicone, Viton |
Dimensions:
Nominal Lengths |
20, 40 & 60 inches |
Diameter: ID/OD |
3" (76 mm) / 6.5" (165 mm) |
End connections |
DOE (standard) / SOE (optional) |
Max operating temperature |
80 OC |
Max Change Out Differential Pressure |
50 PSID (3.5 bar) |
Recommended Change out differential pressure |
35 PSID (2.5 bar) |